Accessories
Reliable Aquatic Systems For Life Under The Surface
Aqua Logic offers thoughtfully designed accessories to help you achieve the most precise temperature control and safeguard your equipment.
We also fabricate PVC water stop flanges and offer other custom plastic and metal fabrications.
Browse our selection below or Contact Us for special requests.
Titanium Sensor Wells
Titanium Sensor Wells
Titanium Sensor Wells
Titanium Sensor Wells
Our Titanium Dry Sensor Wells are the last sensor well you’ll ever buy because they will not rust and corrode, even in saltwater applications.
Made to your specifications, they are available in three standard diameters and can be customized from there to meet your system requirements.
Call to speak with a member of our sales team today about ordering or inquire below.
- Features
- Sizing
- Specifications
- Product Literature
- Product Inquiry
FEATURES:
- All Titanium fabrication
- Choice of 3 standard well diameters
- Custom lengths
- Custom internal/external threaded connections
The following information is required to order a custom Dry Sensor Well:
1. Select from 3 standard well diameters:
3/8"
1/2"
3/4"
2. Select outer thread size
1/2", 3/4", or 1"
3. Select inner thread size
1/4", 1/2", 3/4", or 1"
4. Select a sensor well length
i.e. 4.5"
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.
Temperature Controllers
Digital Temperature Controllers
Digital Temperature Controllers
Aqua Logic’s digital temperature controllers can be used in a variety of applications where a device needs to be turned on / off based on temperature rise or fall.
The Single Stage controller is for use with only one device, a chiller or a heater for example.
The Dual Stage controller can be connected to both a chiller and heater, but only allows one of the devices to be on at one time.
Select Models available for sale in online store. See drop down menu. For larger sizes please contact us for assistance with sizing and purchase.
Digital Temperature Controllers
$177.00 – $249.00
- Features
- Sizing
- Product Literature
- Product Inquiry
- Controls chilling or heating equipment
- Push button controls for easy programming of set points, differential, and heating/cooling mode
- Keypad lockout to prevent tampering
- Non-volatile memory retains control settings during power outages
- Programmable in Fahrenheit or Celsius
- Differential programmable to 1ºF
- Titanium encapsulated sensor for maximum protection from water
- Microprocessor based operation for accurate temperature settings.
- Includes power cord and remote sensor on 8ft cable
- NEMA 4x rated water tight enclosure protects internal electrical
- Rated for indoor/outdoor use
- Easy plug in design (most models)
The following tables serve as a guideline for choosing the correct controller for your Aqua Logic equipment. Please contact us if you need further assistance.
Single-stage Digital Controllers:
NOTE:
*AMP LOAD CAPACITY.
Duel-stage Digital Controllers:
NOTE:
*AMP LOAD CAPACITY.
- INSTRUCTIONS-Single Stage Temperature Controller
- INSTRUCTIONS-Dual Stage Temperature Controller
- INSTRUCTIONS- DC Series Single Stage Temperature Controller
- INSTRUCTIONS- DC Series Dual Stage Temperature Controller
- INSTRUCTIONS- DC Series Single Stage RAW Replacement Controller for all MT Chillers and DX HEX (Model DC24S)
- INSTRUCTIONS- DC Series Dual Stage Temperature Controller for HEAT PUMPS
- SPEC SHEET- DC115-20 & DC230S Temperature Controller
- SPEC SHEET- ADC-4-220 Temperature Controller
- SPEC SHEET-ADC-6-220 Temperature controller
- SPEC SHEET-ADC-12-2201 Temperature Controller
- SPEC SHEET-TR115DN Temperature Controller
- SPEC SHEET-TR115SN Temperature Controller
- SPEC SHEET-TR230SN Temperature Controller
- SPEC SHEET-TRDN24 Temperature Controller w/ bare sensor
- SPEC SHEET-TRSN & TRDN Temperature Controllers
- SPEC SHEET-TRSN24 Temperature Controller w/ bare sensor & Titanium sensor well
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.
Temperature Controller Accessories
Temperature Controller Accessories
Flow Switches
Water Flow Switches
Water Flow Switches
Aqua Logic’s water flow switches are the best way to safe guard your equipment if the pump is mistakenly turned off or fails. Freeze damage to a heat exchanger is not covered by warranties and the resulting water damage that occurs when the unit thaws out, can mean costly repairs or replacement of your chiller. A UV sterilizer can overheat and electrical components will be irreparably damaged if water flow is cut off. These inexpensive and easy to install water flow switches are great insurance. When water flow stops the switch will automatically turn off the equipment you have it connected to.
Select Models available for sale in online store. See drop down menu. For larger sizes please contact us for assistance with sizing and purchase.
Water Flow Switches
$176.00 – $282.00
- Features
- Product Literature
- Product Inquiry
- Easy to Install
- For Both Fresh & Salt Water
- PVC slip sockets
- Pre-Wired with Cord Ends
- PVC and Titanium Construction
- Protect Against No Flow Freeze Damage to in-line chiller
- Protect UV sterilizer from heat damage if pump fails
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.
Water Stop Flanges
PVC Water Stop Flanges
PVC Water Stop Flanges
Aqua Logic manufactures PVC water stop flanges for use with pipe penetrations through walls and floors of hydraulic structures, and exteriors.
- Reservoirs
- Backwash Recovery
- Concrete Ozone Towers
- Exhibits
- Skimmers
- Sumps
- Slabs on grade
PVC Water Stop Flanges
- Features
- Sizing
- Specifications
- Product Literature
- Product Inquiry
- All PVC pipe used is Schedule 80 (NSF and ASTM-D-1784/ASTM-D-1785)
- All PVC flanges are Type 1, dark grey (ASTM-D-1784/ASTM-D-792) with a minimum thickness and projections as shown in drawings.
- Flanges are thermally fused circumferentially to the outside of the PVC pipe using Type 1 welding rod
- Aqua Logic Water Stop Flanges are manufactured by Aqua Logic in San Diego, CA.
Select your water stop flange from the table below. Contact us for pipe diameters greater than 24”.
Interested in this product line? Just fill out the form below and we'll get in touch shortly with answers to your questions and solutions for your problems.